US series · 120/240Vac split-phase inverter

ELE GES48160M300-500XP16kW split-phase control with 24kW of PV input.

Documented for 120/240Vac L1+L2+N+PE systems with a 48V battery platform, dual 36A MPPT channels, AC coupling and 1 to 6 unit parallel operation.

US seriesSplit-phase48V battery1–6 units
Representative white ELECNO split-phase hybrid inverter family housing with display
AC output120/240VSplit-phase L1+L2+N+PE
PV input24kWDual 36A MPPT channels

Family visual · confirm image and current document revision for the exact supplied unit

16000WRated output table value
9600WSame-phase output
24000VAPeak per phase
1–6Parallel units

Selection answer

High-output split-phase capacity with documented parallel expansion.

The model fits a documented higher-output split-phase branch using L1, L2, neutral and protective earth. The brochure publishes separate per-phase and same-phase output values, so load balance and the parallel topology must follow the current manual rather than an inferred total rating.

01

Confirm split-phase service

Rated output is 120/240Vac with an L1+L2+N+PE connection.

Do not treat it as 120Vac single phase
02

Use both output rows

The table lists 16000W per phase and 9600W for same-phase output.

Verify load-balance rules
03

Keep PV inside 500V

Maximum DC input is 12000W + 12000W through dual 36A MPPT channels.

MPPT operates at 90-450V
04

Engineer the parallel group

The brochure lists 1 to 6 units; wiring and coordination require the current manual.

Confirm approved topology

Documented operating paths

PV and battery coordinated across L1, L2 and neutral.

The brochure lists AC coupling, CT anti-backflow, on-grid, off-grid, battery-less and parallel operation. Final conductor sizing, neutral behavior, protection and load allocation must follow current documentation.

System overviewELE GES48160M300-500XP
01 / Solar input

PV array

90-500V input range

Dual 36A MPPT channels

PV → inverter

02 / Energy conversion

Split-phase inverter

ELE GES48160M300-500XP

Representative ELECNO inverter family housing
16000Wtable rating

24000VA peak per phase

Family visual · exact unit may vary
03 / Energy storage

48V battery

300A max charge

340A max discharge

Battery ↔ inverter

04 / AC connection

Split-phase loads

120/240Vac output

L1+L2+N+PE

Inverter → load interfaces

Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.

Model specification

Published values tied to ELE GES48160M300-500XP.

Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model revision before PV design, battery integration, split-phase load allocation, parallel design or installation.

01

DC input / PV

Maximum DC input power
12000W + 12000W
Maximum DC input voltage
500V
Start voltage
120V
PV input voltage range
90-500V
MPPT voltage range
90-450V
MPPT channels
2
Maximum MPPT input current
36A + 36A
Maximum PV charging current
300A
02

AC input and output

Per-phase AC input range
85-140Vac
Input frequency range
47-55Hz / 57-65Hz
Maximum per-phase input current
90Aac
Maximum AC charge current
200Adc
Rated output power (per phase)
16000W
Rated output (same phase)
9600W
Peak power (per phase)
24000VA
Rated output voltage
120/240Vac
Output frequency
50/60Hz
Power factor
1
Connection
L1+L2+N+PE
03

Battery parameters

Rated battery voltage
51.2V
Minimum start voltage
44V
Battery voltage range
40-60Vdc
Battery type
Lead-acid / lithium
Maximum charge / discharge
300A / 340A
Charge voltage range
40-60Vdc
Battery-less operation
Yes
PV / grid battery activation
Listed feature
04

General data

Dimensions (W × D × H)
720 × 482 × 149mm
Weight
37.5kg
Operating temperature
-10°C to 55°C
Derating
Above 45°C
Storage temperature
-25°C to 60°C
Humidity range
5%-95%
Cooling
Forced air, variable speed
Protection class / noise
IP21 / ≤60dB
05

Protection and transfer

Grid overload protection
Circuit breaker
Grid breaker rating
100A
AC reverse feed protection
Yes
Charge short-circuit protection
Fuse
AC output short-circuit protection
Yes
Wiring protection
Yes
Transfer time
10ms typical
CT anti-backflow
Yes
06

Interfaces and limits

Communication ports
USB / RS485 / Wi-Fi / CAN
AC coupling
Yes
Dry contact control
Yes
Remote diagnostics / OTA
Yes
Parallel units
1 to 6 units
Maximum altitude
4000m
No-derating altitude
≤2000m
Maximum efficiency
>93.5% battery to load
Phases
Split-phase

Brochure-listed functions

High-output split-phase capability with explicit boundaries.

These functions are listed on the supplied model page. Availability, firmware behavior, accessories and configuration should be checked against the current supplied package.

Check project compatibility
01

120/240Vac split-phase output

The table lists L1+L2+N+PE, 16000W rated output per phase and 9600W same-phase output. Confirm load allocation rules.

02

AC coupling and CT anti-backflow

Both functions are listed. Confirm CT selection, placement, source coordination and commissioning method.

03

Dual 36A / 24kW PV input

PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.

04

24000VA peak per phase

The brochure describes a 150% surge peak for 5 seconds. Verify the actual phase load and starting profile.

05

1 to 6 unit parallel operation

The brochure also states expansion up to 72kW. Confirm the approved topology, firmware and accessories.

Before specification

Higher output and battery current require system-level review.

The brochure publishes per-phase and same-phase values and lists 1 to 6 parallel units. Preserve those labels and obtain the current load-balance and parallel documentation before design.

01

Split-phase loads

Document L1, L2, 240V and neutral loads separately, including continuous and starting demand.

02

PV string Voc

Calculate cold-weather open-circuit voltage and keep each MPPT inside the documented limits.

03

Battery and BMS

Confirm model, 40-60Vdc window, 300A/340A current, CAN/RS485 protocol, cables and protection.

04

Parallel topology

Confirm unit count, phase assignment, synchronization, protection, firmware and required accessories.

05

Documents

Request the current datasheet, parallel manual and applicable certificate scope for the target market.

Certification note

The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.

Model FAQ

Answers tied to ELE GES48160M300-500XP.

The supplied model page controls the answers below. Project suitability still depends on the complete split-phase, PV, battery, parallel and protection design.

Yes. The brochure lists 120/240Vac output, split-phase operation and an L1+L2+N+PE connection.

Model-specific inquiry

Send the load schedule and parallel plan.

Include country, 120V and 240V loads, neutral requirements, unit count, phase topology, PV strings, battery model, quantity and required documents. The inquiry form will prefill this model number.

Request ELE GES48160M300-500XP data