US series · 120/240Vac split-phase inverter

ELE GES4862M120-500Split-phase output with 9kW of PV input.

Documented for 120/240Vac L1+L2+N+PE systems with a 48V battery platform, one 27A MPPT channel and AC coupling. Parallel operation is not supported.

US seriesSplit-phase48V batteryNo parallel
Representative white ELECNO split-phase hybrid inverter family housing with round display
AC output120/240VSplit-phase L1+L2+N+PE
PV input9kWOne 27A MPPT channel

Family visual · confirm image and current document revision for the exact supplied unit

6200WRated output table value
4800WSame-phase output
9300VAPeak per phase
NoParallel operation

Selection answer

A dedicated 120/240Vac architecture, not a 120Vac substitute.

The model fits a documented split-phase branch using L1, L2, neutral and protective earth. The brochure publishes separate per-phase and same-phase output values, so load balance must be checked from the current datasheet rather than inferred from the model name.

01

Confirm split-phase service

Rated output is 120/240Vac with an L1+L2+N+PE connection.

Do not treat it as single phase
02

Use both output rows

The table lists 6200W per phase and 4800W for same-phase output.

Verify load-balance rules
03

Keep PV inside 500V

Maximum DC input is 9kW through one 27A MPPT channel.

MPPT operates at 90-450V
04

Do not design a parallel bank

Parallel units are explicitly listed as not supported for this model.

Select another documented model

Documented operating paths

PV and battery coordinated across L1, L2 and neutral.

The brochure lists AC coupling, CT anti-backflow, on-grid, off-grid and battery-less operation. Final conductor sizing, neutral behavior, protection and load allocation must follow current documentation.

System overviewELE GES4862M120-500
01 / Solar input

PV array

90-500V input range

One 27A MPPT channel

PV → inverter

02 / Energy conversion

Split-phase inverter

ELE GES4862M120-500

Representative ELECNO inverter family housing
6200Wtable rating

9300VA peak per phase

Family visual · exact unit may vary
03 / Energy storage

48V battery

120A max charge

140A max discharge

Battery ↔ inverter

04 / AC connection

Split-phase loads

120/240Vac output

L1+L2+N+PE

Inverter → load interfaces

Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.

Model specification

Published values tied to ELE GES4862M120-500.

Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model revision before PV design, battery integration, split-phase load allocation or installation.

01

DC input / PV

Maximum DC input power
9000W
Maximum DC input voltage
500V
Start voltage
120V
PV input voltage range
90-500V
MPPT voltage range
90-450V
MPPT channels
1
Maximum MPPT input current
27A
Maximum PV charging current
120A
02

AC input and output

Per-phase AC input range
85-140Vac
Input frequency range
47-55Hz / 57-65Hz
Maximum per-phase input current
40Aac
Maximum AC charge current
100Adc
Rated output power (per phase)
6200W
Rated output (same phase)
4800W
Peak power (per phase)
9300VA
Rated output voltage
120/240Vac
Output frequency
50/60Hz
Power factor
1
Connection
L1+L2+N+PE
03

Battery parameters

Rated battery voltage
51.2V
Minimum start voltage
44V
Battery voltage range
40-60Vdc
Battery type
Lead-acid / lithium
Maximum charge / discharge
120A / 140A
Charge voltage range
40-60Vdc
Battery-less operation
Yes
PV / grid battery activation
Listed feature
04

General data

Dimensions (W × D × H)
420 × 330 × 122mm
Weight
12kg
Operating temperature
-10°C to 55°C
Derating
Above 45°C
Storage temperature
-25°C to 60°C
Humidity range
5%-95%
Cooling
Forced air, variable speed
Protection class / noise
IP21 / ≤60dB
05

Protection and transfer

Grid overload protection
Circuit breaker
Grid breaker rating
40A
AC reverse feed protection
Yes
Charge short-circuit protection
Fuse
AC output short-circuit protection
Yes
Wiring protection
Yes
Transfer time
10ms typical
CT anti-backflow
Yes
06

Interfaces and limits

Communication ports
USB / RS485 / Wi-Fi / CAN
AC coupling
Yes
Dry contact control
Yes
Remote diagnostics / OTA
Yes
Parallel units
Not supported
Maximum altitude
4000m
No-derating altitude
≤2000m
Maximum efficiency
>92.5% battery to load
Phases
Split-phase

Brochure-listed functions

Split-phase capability with explicit output boundaries.

These functions are listed on the supplied model page. Availability, firmware behavior, accessories and configuration should be checked against the current supplied package.

Check project compatibility
01

120/240Vac split-phase output

The table lists L1+L2+N+PE, 6200W rated output per phase and 4800W same-phase output. Confirm load allocation rules.

02

AC coupling and CT anti-backflow

Both functions are listed. Confirm CT selection, placement, source coordination and commissioning method.

03

Single 27A / 9000W PV channel

PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.

04

9300VA peak per phase

The brochure describes a 150% surge peak for 5 seconds. Verify the actual phase load and starting profile.

05

Generator and battery-less modes

Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.

Before specification

Do not infer total output from one table row.

The brochure publishes per-phase and same-phase values without an independent combined-rating explanation. Preserve those labels and obtain the current load-balance documentation before design.

01

Split-phase loads

Document L1, L2, 240V and neutral loads separately, including continuous and starting demand.

02

PV string Voc

Calculate cold-weather open-circuit voltage and keep it within the documented maximum.

03

Battery and BMS

Confirm model, 40-60Vdc window, 120A/140A current, CAN/RS485 protocol and cable pinout.

04

No parallel operation

The model is explicitly listed as not supporting parallel units; do not plan multi-unit expansion.

05

Documents

Request the current datasheet, manual and applicable certificate scope for the target market.

Certification note

The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.

Model FAQ

Answers tied to ELE GES4862M120-500.

The supplied model page controls the answers below. Project suitability still depends on the complete split-phase, PV, battery and protection design.

Yes. The brochure lists 120/240Vac output, split-phase operation and an L1+L2+N+PE connection.

Model-specific inquiry

Send the L1 and L2 load schedule.

Include country, 120V and 240V loads, neutral requirements, PV strings, battery model, quantity and required documents. The inquiry form will prefill this model number.

Request ELE GES4862M120-500 data