EU series · residential hybrid inverter

ELE SPI2436V120-5003.6kW control on a 24V battery platform.

Documented for 230Vac single-phase residential systems with 6kW maximum DC input, one 27A MPPT channel and battery-less operating capability.

EU seriesSingle-phase24V batteryNo parallel
Representative white ELECNO residential hybrid inverter family housing
PV input6kW500V maximum DC voltage
Battery24V20-33Vdc operating range

Family visual · confirm image and current document revision for the exact supplied unit

3.6kWRated AC output
230VacSingle-phase output
1 × 27AMPPT channel
10msTypical transfer

Selection answer

A compact model with clear electrical boundaries.

The model fits a documented 230Vac single-phase branch where a 24V battery platform and 3.6kW rated output are appropriate. It is not the right choice when the design requires parallel inverter expansion.

01

Start with the AC service

Rated output is 230Vac, single-phase, L+N+PE at 50/60Hz.

Confirm country and grid rules
02

Check the battery window

The brochure lists 20-33Vdc and lead-acid or lithium battery types.

Nominal voltage is not enough
03

Keep PV inside limits

Maximum DC input is 6kW; PV Voc must remain below 500V.

Cold-weather Voc controls
04

Do not design a parallel bank

Parallel units are explicitly listed as not supported for this model.

Select another documented model

Documented operating paths

Solar, battery, grid and backup are one coordinated system.

The brochure lists on-grid, off-grid and battery-less operating capability. The final wiring, protection and operating mode must follow the current installation documentation.

System overviewELE SPI2436V120-500
01 / Solar input

PV array

90-500V input range

90-450V MPPT range

PV → inverter

02 / Energy conversion

Hybrid inverter

ELE SPI2436V120-500

Representative ELECNO inverter family housing
3600Wrated output

7200VA peak for 5s

Family visual · exact unit may vary
03 / Energy storage

24V battery

120A max charge

140A max discharge

Battery ↔ inverter

04 / AC connection

Loads / grid

230Vac single-phase

10ms typical transfer

Grid input · load output

Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.

Model specification

Every published value tied to one model.

Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest datasheet revision before procurement, string design or installation.

01

DC input / PV

Maximum DC input power
6000W
Maximum DC input voltage
500V
Start voltage
120V
PV input voltage range
90-500V
MPPT voltage range
90-450V
MPPT channels
1
Maximum MPPT input current
27A
Maximum PV charging current
120A
02

AC input and output

AC input range
170-280Vac
Input frequency range
47-55Hz / 57-65Hz
Maximum AC input current
30Aac
Maximum AC charge current
80Adc
Rated AC output power
3600W
Maximum AC output power
3600VA
Peak power / duration
7200VA / 5s
Rated output voltage
230Vac
Output frequency
50/60Hz
Connection
L+N+PE
03

Battery parameters

Rated battery voltage
28.8Vdc
Minimum start voltage
22V
Battery voltage range
20-33Vdc
Battery type
Lead-acid / lithium
Maximum charge / discharge
120A / 140A
Charge voltage range
20-33Vdc
Battery-less operation
Yes
PV / grid battery activation
Listed feature
04

General data

Dimensions (W × D × H)
428 × 280 × 110mm
Weight
8.2kg
Operating temperature
-10°C to 55°C
Derating
Above 45°C
Storage temperature
-25°C to 60°C
Humidity range
5%-95%
Cooling
Forced air, variable speed
Protection class
IP21
Noise
≤60dB
05

Protection and transfer

Grid overload protection
Circuit breaker
Grid breaker rating
30A
AC reverse feed protection
Yes
Battery short-circuit protection
Fuse
AC output short-circuit protection
Yes
Wiring protection
Yes
Transfer time
10ms typical
CT anti-backflow
Yes
06

Interfaces and limits

Communication ports
USB / RS485 / Wi-Fi
Dry contact control
Yes
Remote diagnostics / OTA
Yes
Parallel units
Not supported
Maximum altitude
4000m
No-derating altitude
≤2000m
Maximum efficiency
>93% battery to load
Power factor
1

Brochure-listed functions

Useful functions, stated with their limits visible.

These are model-page claims in the supplied brochure. Availability, firmware behavior and accessories should be checked against the current supplied configuration.

Check project compatibility
01

CT anti-backflow

Zero feed-in protection is listed; confirm CT selection, placement and commissioning method.

02

200% surge for 5 seconds

7200VA peak output is listed; verify the actual starting profile of motors and other critical loads.

03

Peak shaving and tariff management

Operating schedules still depend on metering, grid policy and the available configuration.

04

Dry-contact generator control

The brochure lists dry-contact control. Generator sizing and charge behavior require project review.

05

Battery-less operation

PV plus grid direct supply is listed; available behavior depends on solar and grid conditions.

Before specification

Five checks remain project-specific.

A model page narrows the choice; it does not replace system design, local compliance review or the current installation manual.

01

PV string Voc

Calculate cold-weather open-circuit voltage and keep it within the documented maximum.

02

Battery and BMS

Confirm model, voltage window, current, communication protocol, firmware and cable pinout.

03

Backup loads

List continuous loads, the largest surge, transfer sensitivity and required backup duration.

04

Grid and protection

Confirm country, service voltage, earthing, isolation, protection and anti-islanding requirements.

05

Documents

Request the current datasheet, manual and applicable certificate scope for the target market.

Certification note

The brochure specification table references CE (IEC 62109-1, -2), IEC 61000 and C2. This website does not present those references as independently verified certificates. Request the applicable certificate, model scope and revision before relying on a compliance claim.

Model FAQ

Answers tied to ELE SPI2436V120-500.

The supplied model page controls the answers below. Project suitability still depends on the complete electrical design.

Yes. The brochure lists a 24V nominal platform, 28.8Vdc rated battery voltage and a 20-33Vdc battery range. Confirm the exact battery and BMS separately.

Model-specific inquiry

Confirm the system around the model.

Send the country, PV strings, battery model, backup loads, quantity and documents required. The inquiry form will prefill this model number.

Request ELE SPI2436V120-500 data