EU series · high-output residential inverter

ELE SPI48120V150-500P12kW output with 18kW dual-MPPT PV input.

Documented for 230Vac single-phase systems with a 48V battery platform, two 27A MPPT channels and support for one to six parallel units.

EU seriesSingle-phase48V battery1-6 parallel
Representative white ELECNO residential hybrid inverter family housing with display
PV input18kWTwo 9kW MPPT channels
Battery platform48V150A / 260A max charge / discharge

Family visual · confirm image and current document revision for the exact supplied unit

12kWRated AC output
18kWMaximum PV input
2 × 27AMPPT channels
1-6Parallel units

Selection answer

A high-output 48V path for 230Vac single-phase projects.

The model fits a documented 12kW single-phase branch where two PV channels, high battery current and a planned parallel expansion path are relevant. Its headline power does not replace PV string, battery, protection or load-surge engineering.

01

Start with 230Vac service

Rated output is single-phase L+N+PE at 50/60Hz.

Confirm country and grid rules
02

Verify the 48V battery

The brochure lists 40-60Vdc and up to 150A charge / 260A discharge.

Check BMS and cable design
03

Divide PV across two MPPTs

Maximum DC input is listed as 9000W + 9000W with 27A per channel.

Cold-weather Voc still controls
04

Engineer parallel expansion

One to six units are listed, but grouping, protection and communications must be confirmed.

Use current model documents

Documented operating paths

Two PV trackers feeding one coordinated energy system.

The brochure lists on-grid, off-grid and battery-less operation. Final strings, protection, battery current, parallel arrangement and operating modes must follow current installation documentation.

System overviewELE SPI48120V150-500P
01 / Solar input

Dual PV input

90-500V input range

2 × 27A MPPT

PV → inverter

02 / Energy conversion

Hybrid inverter

ELE SPI48120V150-500P

Representative ELECNO inverter family housing
12000Wrated output

24000VA peak for 5s

Family visual · exact unit may vary
03 / Energy storage

48V battery

150A max charge

260A max discharge

Battery ↔ inverter

04 / AC connection

Loads / grid

230Vac single-phase

10ms typical transfer

Grid input · load output

Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.

Model specification

Every published value tied to ELE SPI48120V150-500P.

Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest datasheet revision before procurement, string design, parallel planning or installation.

01

DC input / PV

Maximum DC input power
9000W + 9000W
Maximum DC input voltage
500V
Start voltage
120V
PV input voltage range
90-500V
MPPT voltage range
90-450V
MPPT channels
2
Maximum MPPT input current
27A per channel
Maximum PV charging current
150A
02

AC input and output

AC input range
170-280Vac
Input frequency range
47-55Hz / 57-65Hz
Maximum AC input current
60Aac
Maximum AC charge current
150Adc
Rated AC output power
12000W
Maximum AC output power
12000VA
Peak power / duration
24000VA / 5s
Rated output voltage
230Vac
Output frequency
50/60Hz
Power factor
1
Connection
L+N+PE
03

Battery parameters

Rated battery voltage
51.2Vdc
Minimum start voltage
44V
Battery voltage range
40-60Vdc
Battery type
Lead-acid / lithium
Maximum charge / discharge
150A / 260A
Charge voltage range
40-60Vdc
Battery-less operation
Yes
PV / grid battery activation
Listed feature
04

General data

Dimensions (W × D × H)
540 × 350 × 120mm
Weight
19.5kg
Operating temperature
-10°C to 55°C
Derating
Above 45°C
Storage temperature
-25°C to 60°C
Humidity range
5%-95%
Cooling
Forced air, variable speed
Protection class / noise
IP21 / ≤60dB
05

Protection and transfer

Grid overload protection
Circuit breaker
Grid breaker rating
63A
AC reverse feed protection
Yes
Battery short-circuit protection
Fuse
AC output short-circuit protection
Yes
Wiring protection
Yes
Transfer time
10ms typical
CT anti-backflow
Yes
06

Interfaces and scale

Communication ports
USB / RS485 / Wi-Fi
Dry contact control
Yes
Remote diagnostics / OTA
Yes
Parallel units
1-6
Maximum altitude
4000m
No-derating altitude
≤2000m
Maximum efficiency
>94.5% battery to load
Phases
Single-phase

Brochure-listed functions

High current and dual MPPT need disciplined system design.

These functions are listed on the supplied model page. Availability, firmware behavior, parallel accessories and configuration should be checked against the current supplied package.

Check project compatibility
01

18kW across two MPPT channels

The brochure lists 9000W per channel and 27A maximum MPPT input current; actual strings must stay within all voltage and current limits.

02

24000VA peak for 5 seconds

The exact specification-table value is used here. Verify the starting profile of motors and other critical loads.

03

150A charge and 260A discharge

Battery cells, BMS, busbars, cables, fusing and thermal design must support the intended current safely.

04

One to six parallel units

The expansion range is documented; grouping, protection and communication layout still require engineering review.

05

Generator and battery-less modes

Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.

Before specification

12kW on 48V makes current planning essential.

A model page narrows the choice; it does not replace current parallel instructions, conductor sizing, battery verification, local compliance review or installation documentation.

01

PV strings

Assign modules to both MPPTs and calculate cold-weather open-circuit voltage and operating current.

02

Battery and BMS

Confirm the voltage window, 150A/260A current path, protocol, firmware and cable pinout.

03

DC conductors

Size cables, busbars, terminals, fuses and isolation for the project current and installation method.

04

Parallel design

Confirm unit count, grouping, master logic, protection, wiring and communication accessories.

05

Documents

Request the current datasheet, manual and applicable certificate scope for the target market.

Certification note

The brochure specification table references CE (IEC 62109-1, -2), IEC 61000 and C2. This website does not present those references as independently verified certificates. Request the applicable certificate, model scope and revision before relying on a compliance claim.

Model FAQ

Answers tied to ELE SPI48120V150-500P.

The supplied model page controls the answers below. Project suitability still depends on the complete electrical and parallel design.

The brochure lists two MPPT channels with 9000W maximum DC input and 27A maximum MPPT input current per channel.

Model-specific inquiry

Check the current path before selecting the power.

Send the country, PV strings, battery model, cable plan, loads, planned parallel count, quantity and documents required. The inquiry form will prefill this model number.

Request ELE SPI48120V150-500P data