Confirm 120Vac service
Rated output is single-phase L+N+PE at 50/60Hz.
Do not treat it as split phaseUS series · parallel 120Vac inverter
Documented for 120Vac single-phase systems with a 48V battery platform, 6kW PV input, one 27A MPPT channel and support for one to six parallel units.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
The model fits a documented 120Vac single-phase branch where 3.6kW rated output, a 48V battery platform and future parallel grouping are relevant. Its 300V PV ceiling is a strict string-design boundary, not a target.
Rated output is single-phase L+N+PE at 50/60Hz.
Do not treat it as split phaseThe brochure lists 40-60Vdc and 80A/85A maximum charge/discharge.
Verify BMS and conductorsThe MPPT range stops at 260V and cold-weather Voc must remain below 300V.
Calculate the full stringOne to six units are listed, but grouping, protection and communications must be confirmed.
Use current model documentsDocumented operating paths
The brochure lists on-grid, off-grid and battery-less operation. Final PV strings, protection, 120Vac service, parallel arrangement and operating modes must follow current installation documentation.
90-300V input range
90-260V MPPT range
PV → inverter
02 / Energy conversion
ELE SPI4836M80-300P

5400VA peak for 5s
Family visual · exact unit may vary80A max charge
85A max discharge
Battery ↔ inverter
120Vac single-phase
10ms typical transfer
Grid input · load output
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model and market revision before procurement, PV design, parallel planning or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, parallel accessories and configuration should be checked against the current supplied package.
Check project compatibility →The brochure mentions split-phase or three-phase grouping up to 21.6kW; exact topology, accessories and approval require the current parallel documentation.
PV open-circuit voltage must remain below 300V and operating voltage inside the 90-260V MPPT range.
The exact table value is used here. Verify the starting profile of motors and other critical loads.
Confirm CT selection, placement, utility rules, operating schedule and commissioning method.
Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.
Before specification
A matching headline value is not enough. Check each electrical domain independently and design parallel operation only from the current model documentation.
Calculate cold-weather open-circuit voltage and keep it below the documented 300V maximum.
Confirm model, 40-60Vdc window, current, protocol, firmware and communication cable pinout.
Confirm country, single-phase service, frequency, neutral, earthing and grid requirements.
Confirm unit count, phase grouping, master logic, protection, wiring and communication accessories.
Request the current datasheet, manual and applicable certificate scope for the target market.
The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.
Model FAQ
The supplied model page controls the answers below. Project suitability still depends on the complete AC, PV, battery and parallel design.
The brochure lists 300V maximum DC input voltage, a 90-300V PV input range and a 90-260V MPPT range.
Yes. The table lists 48Vdc rated battery voltage, a 40-60Vdc range and 80A/85A maximum charge/discharge current.
The brochure lists one to six units. The actual grouping, protection, phase arrangement, wiring and communications must follow the current manual.
The table lists 3600W rated output at 120Vac single-phase and 5400VA peak power for 5 seconds.
Send the destination country, model, AC service, PV strings, battery, planned parallel arrangement and required documents through the inquiry form.
Model-specific inquiry
Send the country, AC service, PV strings, battery model, loads, planned parallel count, quantity and documents required. The inquiry form will prefill this model number.
Request ELE SPI4836M80-300P data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy