Confirm split-phase service
Rated output is 120/240Vac with an L1+L2+N+PE connection.
Do not treat it as single phaseUS series · 120/240Vac split-phase inverter
Documented for 120/240Vac L1+L2+N+PE systems with a 48V battery platform, one 27A MPPT channel and AC coupling. Parallel operation is not supported.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
The model fits a documented split-phase branch using L1, L2, neutral and protective earth. The brochure publishes separate per-phase and same-phase output values, so load balance must be checked from the current datasheet rather than inferred from the model name.
Rated output is 120/240Vac with an L1+L2+N+PE connection.
Do not treat it as single phaseThe table lists 6200W per phase and 4800W for same-phase output.
Verify load-balance rulesMaximum DC input is 9kW through one 27A MPPT channel.
MPPT operates at 90-450VParallel units are explicitly listed as not supported for this model.
Select another documented modelDocumented operating paths
The brochure lists AC coupling, CT anti-backflow, on-grid, off-grid and battery-less operation. Final conductor sizing, neutral behavior, protection and load allocation must follow current documentation.
90-500V input range
One 27A MPPT channel
PV → inverter
02 / Energy conversion
ELE GES4862M120-500

9300VA peak per phase
Family visual · exact unit may vary120A max charge
140A max discharge
Battery ↔ inverter
120/240Vac output
L1+L2+N+PE
Inverter → load interfaces
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model revision before PV design, battery integration, split-phase load allocation or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, accessories and configuration should be checked against the current supplied package.
Check project compatibility →The table lists L1+L2+N+PE, 6200W rated output per phase and 4800W same-phase output. Confirm load allocation rules.
Both functions are listed. Confirm CT selection, placement, source coordination and commissioning method.
PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.
The brochure describes a 150% surge peak for 5 seconds. Verify the actual phase load and starting profile.
Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.
Before specification
The brochure publishes per-phase and same-phase values without an independent combined-rating explanation. Preserve those labels and obtain the current load-balance documentation before design.
Document L1, L2, 240V and neutral loads separately, including continuous and starting demand.
Calculate cold-weather open-circuit voltage and keep it within the documented maximum.
Confirm model, 40-60Vdc window, 120A/140A current, CAN/RS485 protocol and cable pinout.
The model is explicitly listed as not supporting parallel units; do not plan multi-unit expansion.
Request the current datasheet, manual and applicable certificate scope for the target market.
The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.
Model FAQ
The supplied model page controls the answers below. Project suitability still depends on the complete split-phase, PV, battery and protection design.
Yes. The brochure lists 120/240Vac output, split-phase operation and an L1+L2+N+PE connection.
The table labels 6200W as rated output per phase and 4800W as same-phase output. This page does not calculate an unstated combined rating.
No. Parallel units are listed as not supported. Choose a documented parallel-capable split-phase model if expansion is required.
The brochure lists 9000W maximum DC input, one 27A MPPT channel, a 48V battery platform and 120A/140A maximum charge/discharge current.
Send the destination country, split-phase service, L1/L2 load schedule, PV strings, battery and required documents through the inquiry form.
Model-specific inquiry
Include country, 120V and 240V loads, neutral requirements, PV strings, battery model, quantity and required documents. The inquiry form will prefill this model number.
Request ELE GES4862M120-500 data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy