Confirm 120Vac service
Rated output is single-phase L+N+PE at 50/60Hz.
Do not treat it as split phaseUS series · high-output 120Vac inverter
Documented for 120Vac single-phase systems with a 48V battery platform, one 27A MPPT channel, CAN communication and support for one to six parallel units.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
The model fits a documented 120Vac single-phase branch where 6.2kW rated output, 9kW PV capacity and planned parallel expansion are relevant. Parallel grouping does not change the need to verify the exact service and phase architecture.
Rated output is single-phase L+N+PE at 50/60Hz.
Do not treat it as split phaseThe brochure lists 40-60Vdc and 120A/140A maximum charge/discharge.
Verify BMS and conductorsMaximum DC input is 9kW; cold-weather Voc must remain below 500V.
MPPT operates at 90-450VOne to six units are listed, but grouping, protection and communications must be confirmed.
Use current model documentsDocumented operating paths
The brochure lists on-grid, off-grid and battery-less operation. Final PV strings, battery communication, protection, parallel arrangement and operating modes must follow current installation documentation.
90-500V input range
90-450V MPPT range
PV → inverter
02 / Energy conversion
ELE SPI4862M120-500P

9300VA peak for 5s
Family visual · exact unit may vary120A max charge
140A max discharge
Battery ↔ inverter
120Vac single-phase
10ms typical transfer
Grid input · load output
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model and market revision before procurement, PV design, battery integration, parallel planning or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, parallel accessories and configuration should be checked against the current supplied package.
Check project compatibility →The brochure mentions split-phase or three-phase grouping up to 37.2kW; exact topology, accessories and approval require current parallel documentation.
PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.
The exact table value is used here. Verify the starting profile of motors and other critical loads.
Interfaces are listed, but battery protocol, pinout, firmware and accessory scope remain model- and project-specific.
Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.
Before specification
The model is documented at 120Vac single-phase. Parallel capability still requires an approved topology, and a 120/240Vac split-phase project must be evaluated as a separate system architecture.
Confirm country, single-phase service, frequency, neutral, earthing and grid requirements.
Calculate cold-weather open-circuit voltage and keep it within the documented maximum.
Confirm model, 40-60Vdc window, current, CAN/RS485 protocol, firmware and cable pinout.
Confirm unit count, phase grouping, master logic, protection, wiring and communication accessories.
Request the current datasheet, manual and applicable certificate scope for the target market.
The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.
Model FAQ
The supplied model page controls the answers below. Project suitability still depends on the complete AC, PV, battery and parallel design.
The brochure lists 9000W maximum DC input, 500V maximum DC voltage, a 90-500V input range and one 27A MPPT channel.
Yes. The table lists 51.2Vdc rated battery voltage, a 40-60Vdc range and 120A/140A maximum charge/discharge current.
The brochure lists one to six units. The actual grouping, protection, phase arrangement, wiring and communications must follow the current manual.
The table lists 6200W rated output at 120Vac single-phase and 9300VA peak power for 5 seconds.
Send the destination country, AC service, PV strings, battery, planned parallel arrangement and required documents through the inquiry form.
Model-specific inquiry
Send the country, AC service, PV strings, battery model, loads, planned parallel count, quantity and documents required. The inquiry form will prefill this model number.
Request ELE SPI4862M120-500P data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy