US series · high-output 120Vac inverter

ELE SPI4862M120-500P6.2kW output with 9kW of PV input.

Documented for 120Vac single-phase systems with a 48V battery platform, one 27A MPPT channel, CAN communication and support for one to six parallel units.

US series120Vac48V battery1-6 parallel
Representative white ELECNO residential hybrid inverter family housing with round display
PV input9kW500V maximum DC voltage
Battery platform48V120A / 140A max charge / discharge

Family visual · confirm image and current document revision for the exact supplied unit

6.2kWRated AC output
120VacSingle-phase output
1 × 27AMPPT channel
1-6Parallel units

Selection answer

More 120Vac output on a 48V battery platform.

The model fits a documented 120Vac single-phase branch where 6.2kW rated output, 9kW PV capacity and planned parallel expansion are relevant. Parallel grouping does not change the need to verify the exact service and phase architecture.

01

Confirm 120Vac service

Rated output is single-phase L+N+PE at 50/60Hz.

Do not treat it as split phase
02

Check the 48V battery

The brochure lists 40-60Vdc and 120A/140A maximum charge/discharge.

Verify BMS and conductors
03

Keep PV inside 500V

Maximum DC input is 9kW; cold-weather Voc must remain below 500V.

MPPT operates at 90-450V
04

Engineer parallel expansion

One to six units are listed, but grouping, protection and communications must be confirmed.

Use current model documents

Documented operating paths

PV, battery and 120Vac loads in one coordinated path.

The brochure lists on-grid, off-grid and battery-less operation. Final PV strings, battery communication, protection, parallel arrangement and operating modes must follow current installation documentation.

System overviewELE SPI4862M120-500P
01 / Solar input

PV array

90-500V input range

90-450V MPPT range

PV → inverter

02 / Energy conversion

Hybrid inverter

ELE SPI4862M120-500P

Representative ELECNO inverter family housing
6200Wrated output

9300VA peak for 5s

Family visual · exact unit may vary
03 / Energy storage

48V battery

120A max charge

140A max discharge

Battery ↔ inverter

04 / AC connection

Loads / grid

120Vac single-phase

10ms typical transfer

Grid input · load output

Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.

Model specification

Every published value tied to ELE SPI4862M120-500P.

Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model and market revision before procurement, PV design, battery integration, parallel planning or installation.

01

DC input / PV

Maximum DC input power
9000W
Maximum DC input voltage
500V
Start voltage
120V
PV input voltage range
90-500V
MPPT voltage range
90-450V
MPPT channels
1
Maximum MPPT input current
27A
Maximum PV charging current
120A
02

AC input and output

AC input range
85-140Vac
Input frequency range
47-55Hz / 57-65Hz
Maximum AC input current
60Aac
Maximum AC charge current
100Adc
Rated AC output power
6200W
Maximum AC output power
6200VA
Peak power / duration
9300VA / 5s
Rated output voltage
120Vac
Output frequency
50/60Hz
Power factor
1
Connection
L+N+PE
03

Battery parameters

Rated battery voltage
51.2Vdc
Minimum start voltage
44V
Battery voltage range
40-60Vdc
Battery type
Lead-acid / lithium
Maximum charge / discharge
120A / 140A
Charge voltage range
40-60Vdc
Battery-less operation
Yes
PV / grid battery activation
Listed feature
04

General data

Dimensions (W × D × H)
420 × 330 × 122mm
Weight
12kg
Operating temperature
-10°C to 55°C
Derating
Above 45°C
Storage temperature
-25°C to 60°C
Humidity range
5%-95%
Cooling
Forced air, variable speed
Protection class / noise
IP21 / ≤60dB
05

Protection and transfer

Grid overload protection
Circuit breaker
Grid breaker rating
60A
AC reverse feed protection
Yes
Battery short-circuit protection
Fuse
AC output short-circuit protection
Yes
Wiring protection
Yes
Transfer time
10ms typical
CT anti-backflow
Yes
06

Interfaces and scale

Communication ports
USB / RS485 / Wi-Fi / CAN
Dry contact control
Yes
Remote diagnostics / OTA
Yes
Parallel units
1-6
Maximum altitude
4000m
No-derating altitude
≤2000m
Maximum efficiency
>92% battery to load
Phases
Single-phase

Brochure-listed functions

More output and more interfaces, with limits visible.

These functions are listed on the supplied model page. Availability, firmware behavior, parallel accessories and configuration should be checked against the current supplied package.

Check project compatibility
01

One to six parallel units

The brochure mentions split-phase or three-phase grouping up to 37.2kW; exact topology, accessories and approval require current parallel documentation.

02

Single 27A / 9000W PV channel

PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.

03

9300VA peak for 5 seconds

The exact table value is used here. Verify the starting profile of motors and other critical loads.

04

USB, RS485, Wi-Fi and CAN

Interfaces are listed, but battery protocol, pinout, firmware and accessory scope remain model- and project-specific.

05

Generator and battery-less modes

Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.

Before specification

Output power does not define the full AC architecture.

The model is documented at 120Vac single-phase. Parallel capability still requires an approved topology, and a 120/240Vac split-phase project must be evaluated as a separate system architecture.

01

120Vac service

Confirm country, single-phase service, frequency, neutral, earthing and grid requirements.

02

PV string Voc

Calculate cold-weather open-circuit voltage and keep it within the documented maximum.

03

Battery and BMS

Confirm model, 40-60Vdc window, current, CAN/RS485 protocol, firmware and cable pinout.

04

Parallel architecture

Confirm unit count, phase grouping, master logic, protection, wiring and communication accessories.

05

Documents

Request the current datasheet, manual and applicable certificate scope for the target market.

Certification note

The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.

Model FAQ

Answers tied to ELE SPI4862M120-500P.

The supplied model page controls the answers below. Project suitability still depends on the complete AC, PV, battery and parallel design.

The brochure lists 9000W maximum DC input, 500V maximum DC voltage, a 90-500V input range and one 27A MPPT channel.

Model-specific inquiry

Define the AC architecture before planning scale.

Send the country, AC service, PV strings, battery model, loads, planned parallel count, quantity and documents required. The inquiry form will prefill this model number.

Request ELE SPI4862M120-500P data