Start with 230Vac service
Rated output is single-phase L+N+PE at 50/60Hz.
Confirm country and grid rulesEU series · parallel residential inverter
Documented for 230Vac single-phase residential systems with 6.5kW maximum DC input, one 27A MPPT channel and support for one to six parallel units.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
The model fits a documented 230Vac single-phase branch where 6.2kW rated output, a 48V battery platform and future parallel expansion are relevant. Parallel capability is a system-design option, not permission to connect units without the current manual.
Rated output is single-phase L+N+PE at 50/60Hz.
Confirm country and grid rulesThe brochure lists 40-60Vdc and lead-acid or lithium battery types.
Verify BMS and currentMaximum DC input is 6.5kW; PV Voc must remain below 500V.
Cold-weather Voc controlsOne to six units are listed, but grouping, protection and communications must be confirmed.
Use current model documentsDocumented operating paths
The brochure lists on-grid, off-grid and battery-less operation. Final wiring, protection, parallel arrangement and operating modes must follow the current installation documentation.
90-500V input range
90-450V MPPT range
PV → inverter
02 / Energy conversion
ELE SPI4862V100-500P

12000VA peak for 5s
Family visual · exact unit may vary100A max charge
135A max discharge
Battery ↔ inverter
230Vac single-phase
10ms typical transfer
Grid input · load output
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest datasheet revision before procurement, string design, parallel planning or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, parallel accessories and configuration should be checked against the current supplied package.
Check project compatibility →The expansion range is documented; phase grouping, protection and communication layout still require engineering review.
The exact specification-table value is used here. Verify the starting profile of motors and other critical loads.
Zero feed-in protection is listed; confirm CT selection, placement and commissioning method.
Operating schedules depend on metering, utility rules, battery limits and the available configuration.
Dry-contact generator control and PV plus grid direct supply are listed; confirm project behavior before design.
Before specification
A model page narrows the choice; it does not replace current parallel instructions, local compliance review or installation documentation.
Calculate cold-weather open-circuit voltage and keep it within the documented maximum.
Confirm model, voltage window, current, protocol, firmware and communication cable pinout.
Confirm unit count, phase grouping, master logic, protection, wiring and communication accessories.
Document continuous loads, peak loads, grid rules, protection and anti-islanding requirements.
Request the current datasheet, manual and applicable certificate scope for the target market.
The brochure specification table references CE (IEC 62109-1, -2), IEC 61000 and C2. This website does not present those references as independently verified certificates. Request the applicable certificate, model scope and revision before relying on a compliance claim.
Model FAQ
The supplied model page controls the answers below. Project suitability still depends on the complete electrical and parallel design.
Yes. The brochure lists a 48V nominal platform, 51.2Vdc rated battery voltage and a 40-60Vdc battery range. Confirm the exact battery and BMS separately.
The brochure lists one to six units. The actual parallel and phase arrangement must follow the current manual and project design.
The brochure lists 6500W maximum DC input, 500V maximum DC voltage, a 90-500V PV input range and one 27A MPPT channel.
Use the exact specification-table value: 12000VA for 5 seconds. Final acceptance still depends on the load starting profile.
Send the model, destination country, planned unit count and project requirements through the inquiry form so the applicable revision can be matched.
Model-specific inquiry
Send the country, PV strings, battery model, loads, planned parallel count, quantity and documents required. The inquiry form will prefill this model number.
Request ELE SPI4862V100-500P data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy