Maximum open-circuit voltage
A ceiling for array Voc—not a normal target and not the MPPT operating value.
Documented EU three-phase range
The current supplied guide confirms one EU three-phase model: ELE TPE48160V300-1000P. This page explains its published selection values and the engineering checks required around them.
Family visualConcept visual · confirm exact output and wiring from model documentation
Three-phase principle
In a typical balanced three-phase system, the phase waveforms are separated by 120 electrical degrees. The load schedule, phase-to-phase and phase-to-neutral requirements still have to match the exact inverter and site.
Current documented model
The neutral guide currently supports this EU model only. No 18kW, 30kW or high-voltage-battery variant is inferred from adjacent products.
Exact image-to-model mapping pending confirmationTPE series · 48V battery
Selection values: Household Series Product — Neutral Version — 260721, EU quick selection guide page 4. Certification scope, exact interfaces and model-image mapping require separate verification.
Voltage-domain check
This model connects two separate DC domains. Treating the PV maximum as the battery voltage would be a fundamental specification error.
A ceiling for array Voc—not a normal target and not the MPPT operating value.
Compatibility still depends on its full operating window, current, BMS and protection.
Calculate maximum string Voc at the lowest design temperature.
Check both documented 36A channels independently.
Verify the bank and BMS against the 300A charging value and discharge design.
Coordinate disconnects, breakers or fuses, conductors and grounding.
Load-side engineering
The 16kW total does not reveal how much uneven phase loading is permitted. Map every load to L1, L2 or L3 and request the exact model limit before promising backup performance.
Send a phase load schedule →Illustrative bars only · not a permitted imbalance specification
Published mode flags
The quick table marks this model for on-grid, off-grid and battery-less operation. Detailed behavior, switching and limitations must still be verified from exact documentation.
Confirm grid settings, anti-export design, protection and target-market requirements.
Selection table: supportedSize continuous load, three-phase motor surge, battery power and reserve energy.
Selection table: supportedRequest exact operating constraints before designing a system without a battery.
Selection table: supportedParallel boundary
Adding inverters multiplies more than nameplate power. It also changes DC current, communications, conductor and busbar sizing, protection, fault levels, layout and commissioning requirements.
Confirm before design: approved topology · firmware · communications · total battery current · AC protection · cable and busbar sizing
Publication status
The model and selection values are consistent enough in the supplied guide to support this category page.
Included on this websiteThe selection table and detail page conflict on the model/current designation. Publishing a product page now would turn an unresolved source conflict into a public claim.
Excluded pending manufacturer confirmationThree-phase FAQ
These answers reflect the current supplied material. The exact datasheet, project design and local electrical requirements remain controlling.
The EU guide documents ELE TPE48160V300-1000P: 16kW output, 48V nominal battery, 300A battery charging, 32kW PV input, 1000V PV Voc maximum, two 36A MPPT channels and 1–6 parallel capability.
No. It is the maximum PV open-circuit voltage. The battery platform is nominal 48V. PV and battery are separate DC domains.
It is the capability stated in the guide, not a complete approval. Confirm firmware, communications, battery current, protection, cabling and the manufacturer-approved architecture for the project.
Not currently. The supplied US selection table and detail page use conflicting model and current designations. That record remains excluded until written confirmation resolves the discrepancy.
This page does not publish an unbalance limit because it is not established by the selection data used here. Submit the load schedule and request the exact datasheet before specifying uneven or single-phase backup loads.
Three-phase inquiry
Include country, grid voltage and frequency, neutral arrangement, loads by phase, largest motor, PV string design, battery model and parallel target.