Confirm split-phase service
Rated output is L1/L2/N 120/240Vac with an L1+L2+N+PE connection.
Confirm neutral and load allocationUS PLUS series · 120/240Vac split-phase inverter
Documented with 24kW dual-MPPT PV input, independent SmartLoad output, a generator interface, AFCI/RSD/ISO functions and 1 to 6 unit parallel operation.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
This model page adds system interfaces that are not established by the standard 12kW headline table: SmartLoad output, generator input, AFCI/RSD/ISO functions and microinverter compatibility. Each path requires current wiring, control and protection documentation.
Rated output is L1/L2/N 120/240Vac with an L1+L2+N+PE connection.
Confirm neutral and load allocationThe load output is listed at 125Adc while the SmartLoad output is listed at 60Adc.
Obtain port wiring rulesThe independent input lists 120/240Vac, 40-70Hz and 160A maximum charge current.
Confirm start/stop controlAFCI, RSD and ISO are brochure-listed special functions, not independent certificate proof.
Request current scopeDocumented operating paths
The brochure lists whole-home backup, SmartLoad, generator input, AC coupling, CT anti-backflow and battery-less operation. Final wiring, switching, neutral behavior and protection must follow current documentation.
12000W + 12000W
Dual 32A MPPT channels
PV → inverter
02 / Energy conversion
ELE GES48120M250-500XP-PLUS

18000VA peak / 5s
Family visual · exact unit may vary250A max charge
270A max discharge
Battery ↔ inverter
Whole-home backup
Independent SmartLoad
Inverter → load interfaces
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model revision before PV design, battery integration, split-phase load allocation, parallel design or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, accessories and configuration should be checked against the current supplied package.
Check project compatibility →The brochure lists whole-home backup and an independent SmartLoad output. Confirm priorities, switching and port limits.
Dry-contact start/stop and generator efficiency boost are listed. Confirm wiring and generator qualification.
PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.
These are brochure-listed special functions. Request exact implementation and applicable compliance evidence.
The brochure lists a compatible input path together with AC coupling. Confirm supported topology and commissioning.
Before specification
This model has a different output table and additional load, generator and protection paths. Obtain the exact manual, firmware and accessory list rather than applying assumptions from the standard 12kW model.
Document both load paths, priorities, continuous current, surge, switching behavior and neutral requirements.
Confirm voltage, frequency, charge current, dry-contact logic, protection and transfer behavior.
Verify hardware, sensing, shutdown behavior, jurisdictional acceptance and exact certificate scope.
Confirm unit count, synchronization, phase arrangement, firmware and required communication accessories.
Do not reuse the standard model manual: output labels, enclosure and interfaces differ, while headline PV capacity remains 24kW.
The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.
Model FAQ
The supplied PLUS model page controls the answers below. Project suitability still depends on the complete load, PV, battery, generator, parallel and protection design.
Yes. The brochure lists 120/240Vac output, split-phase operation and an L1+L2+N+PE connection.
It lists 12000W rated AC output, 12000VA maximum AC output and 18000VA peak power for 5 seconds at L1/L2/N 120/240Vac.
The brochure lists SmartLoad, an independent generator interface, microinverter compatibility and AFCI/RSD/ISO triple protection.
Yes. The brochure lists 1 to 6 units and describes expansion up to 72kW for medium-to-large off-grid projects. Confirm the current approved topology.
Send the country, L1/L2 loads, SmartLoad plan, generator, PV strings, battery, parallel plan and required documents through the inquiry form.
Model-specific inquiry
Include country, L1/L2 loads, neutral requirements, SmartLoad priorities, generator, PV strings, battery, unit count and required documents. The inquiry form will prefill this model number.
Request ELE GES48120M250-500XP-PLUS data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy