Confirm split-phase service
Rated output is 120/240Vac with an L1+L2+N+PE connection.
Do not treat it as 120Vac single phaseUS series · 120/240Vac split-phase inverter
Documented for 120/240Vac L1+L2+N+PE systems with a 48V battery platform, dual 32A MPPT channels, AC coupling and 1 to 6 unit parallel operation.
Family visual · confirm image and current document revision for the exact supplied unit
Selection answer
The model fits a documented higher-PV split-phase branch using L1, L2, neutral and protective earth. The brochure publishes separate per-phase and same-phase output values, so load balance and the parallel topology must follow the current manual rather than an inferred total rating.
Rated output is 120/240Vac with an L1+L2+N+PE connection.
Do not treat it as 120Vac single phaseThe table lists 12000W per phase and 7200W for same-phase output.
Verify load-balance rulesMaximum DC input is 12000W + 12000W through dual 32A MPPT channels.
MPPT operates at 90-450VThe brochure lists 1 to 6 units; wiring and coordination require the current manual.
Confirm approved topologyDocumented operating paths
The brochure lists AC coupling, CT anti-backflow, on-grid, off-grid, battery-less and parallel operation. Final conductor sizing, neutral behavior, protection and load allocation must follow current documentation.
90-500V input range
Dual 32A MPPT channels
PV → inverter
02 / Energy conversion
ELE GES48120M250-500XP

18000VA peak per phase
Family visual · exact unit may vary250A max charge
270A max discharge
Battery ↔ inverter
120/240Vac output
L1+L2+N+PE
Inverter → load interfaces
Functional overview, not an installation wiring diagram. Follow the model-specific manual for terminal assignments and protection.
Model specification
Values below are transcribed from the supplied July 2026 neutral brochure. Confirm the latest model revision before PV design, battery integration, split-phase load allocation, parallel design or installation.
Brochure-listed functions
These functions are listed on the supplied model page. Availability, firmware behavior, accessories and configuration should be checked against the current supplied package.
Check project compatibility →The table lists L1+L2+N+PE, 12000W rated output per phase and 7200W same-phase output. Confirm load allocation rules.
Both functions are listed. Confirm CT selection, placement, source coordination and commissioning method.
PV open-circuit voltage must remain below 500V and operating voltage inside the 90-450V MPPT range.
The brochure describes a 150% surge peak for 5 seconds. Verify the actual phase load and starting profile.
The brochure also states expansion up to 72kW. Confirm the approved topology, firmware and accessories.
Before specification
The brochure publishes per-phase and same-phase values and lists 1 to 6 parallel units. Preserve those labels and obtain the current load-balance and parallel documentation before design.
Document L1, L2, 240V and neutral loads separately, including continuous and starting demand.
Calculate cold-weather open-circuit voltage and keep each MPPT inside the documented limits.
Confirm model, 40-60Vdc window, 250A/270A current, CAN/RS485 protocol, cables and protection.
Confirm unit count, phase assignment, synchronization, protection, firmware and required accessories.
Request the current datasheet, parallel manual and applicable certificate scope for the target market.
The brochure specification table references UL 1741, CSA C22.2 No. 107.1 and FCC Part 15 Class B. This website does not present those references as independently verified certificates. Request the applicable certificate, exact model scope and revision before relying on a compliance claim.
Model FAQ
The supplied model page controls the answers below. Project suitability still depends on the complete split-phase, PV, battery, parallel and protection design.
Yes. The brochure lists 120/240Vac output, split-phase operation and an L1+L2+N+PE connection.
The table labels 12000W as rated output per phase and 7200W as same-phase output. This page does not calculate an unstated combined rating.
Yes. The brochure lists 1 to 6 units and describes expansion up to 72kW. Confirm the current approved topology before design.
The brochure lists 12000W + 12000W maximum DC input, dual 32A MPPT channels, a 48V battery platform and 250A/270A maximum charge/discharge current.
Send the destination country, split-phase service, L1/L2 load schedule, parallel plan, PV strings, battery and required documents through the inquiry form.
Model-specific inquiry
Include country, 120V and 240V loads, neutral requirements, unit count, phase topology, PV strings, battery model, quantity and required documents. The inquiry form will prefill this model number.
Request ELE GES48120M250-500XP data →With your permission, we use Google Analytics to understand page visits and inquiry-button use. We do not send your form answers to analytics. You can change your choice using Analytics preferences in the footer. Privacy policy