US residential power architecture

Split-phase hybrid inverters for 120V and 240V loads.

Eight documented 6.2–16kW models connect solar, a nominal 48V battery platform and a 120/240Vac split-phase service. Select by both load schedule and electrical architecture—not rated power alone.

Split-phase service
L1 → N120V
+
N → L2120V
L1 → L2240V
L1120Vac loads
NNeutral
L2120Vac loads

System concept · exact model wiring remains controlling

8documented models
6.2–16kWrated output range
48Vnominal battery platform
500VPV Voc maximum listed

Quick answer

One service. Two 120V legs. 240V between them.

A typical North American split-phase service uses L1, L2 and neutral. Each line-to-neutral path supplies 120Vac, while a line-to-line circuit supplies 240Vac. The two legs must be treated as one coordinated power system.

L1+120Vline to neutral
N180°opposed legs
L2−120Vline to neutral

240Vline to line

120V circuit

One line + neutral

Typical lighting, receptacle and small-appliance branches.

240V circuit

L1 + L2

Typical larger loads such as selected pumps, HVAC or appliances.

Engineering gate

Balance both legs

Confirm per-leg loading, surge, neutral path and protective devices.

Product boundary

Do not substitute a 120V single-phase model.

The supplied brochure lists SPI single-phase and GES split-phase as separate families. A power rating or battery voltage match does not make their AC outputs interchangeable.

SPI family120Vac

Single-phase branch

  • Four documented US models
  • 3.6–6.5kW range
  • 24V or 48V battery platform
Open single-phase page →
not interchangeable
by label alone
GES family120/240Vac

Split-phase branch

  • Eight documented models
  • 6.2–16kW range
  • 48V battery platform
Compare GES models ↓

Documented model range

Standard and PLUS, kept in exact model groups.

Select up to three models for a side-by-side view. The PLUS suffix is retained exactly; only differences shown in the supplied selection table are summarized.

8 documented split-phase models

Family visual · US splitRepresentative white split-phase hybrid inverter family

48V battery · no parallel

ELE GES4862M120-500

6.2kW
rated output
PV input
9kW
MPPT
1 × 27A
Charge
120A
Parallel
No
View details
Family visual · US splitRepresentative white split-phase hybrid inverter family with display

48V battery · parallel

ELE GES4880M160-500P

8kW
rated output
PV input
10kW
MPPT
2 × 18A
Charge
160A
Parallel
1–6
View details
Family visual · US splitRepresentative white split-phase hybrid inverter family with green display

48V battery · parallel

ELE GES48100M220-500P

10kW
rated output
PV input
12kW
MPPT
2 × 22A
Charge
220A
Parallel
1–6
View details
Family visual · US splitRepresentative white split-phase hybrid inverter family with round display

48V battery · parallel

ELE GES48120M250-500XP

12kW
rated output
PV input
24kW
MPPT
2 × 32A
Charge
250A
Parallel
1–6
View details
Family visual · US splitRepresentative white split-phase hybrid inverter family

48V battery · parallel

ELE GES48160M300-500XP

16kW
rated output
PV input
24kW
MPPT
2 × 36A
Charge
300A
Parallel
1–6
View details

All listed models show 500V maximum PV open-circuit voltage. PV input, MPPT current and battery charging current remain model-specific. Product images are representative family visuals.

Load planning

Build the backup panel circuit by circuit.

A whole-home total hides the detail a split-phase design needs. Separate 120V loads by leg, list every 240V load and identify the largest simultaneous surge.

L1 · 120V
Lightingcontinuous / evening
Receptaclesvariable demand
Refrigerationcompressor surge
Backup load centerBalanceL1 ↔ L2review neutral and protection
L2 · 120V
Lightingcontinuous / evening
Office loadselectronics
Small appliancevariable demand
L1 + L2 · 240V
Pump / HVAC / applianceConfirm running power, starting current and whether it belongs on the backup panel.
01

Per-leg load

Do not assume the total inverter kW is freely available on one 120V leg.

02

240V surge

Separate motor starting from continuous operating power.

03

Neutral path

Confirm topology, conductor sizing and protective arrangement.

04

Transfer design

Verify switching, bonding and local code with the exact system.

DC design envelope

The AC architecture does not size the DC side.

Every documented split-phase model uses a nominal 48V battery platform, but battery current rises across the range. PV capacity and MPPT current also change by model.

Open 48V compatibility guide
Battery platform48Vnominal · all 8 models
Battery charging120–300Amodel-specific range
PV input9–24kWmodel-specific maximum
MPPT1–227A or dual-channel values

These are portfolio ranges, not one model specification. Confirm operating windows, cold-weather PV Voc, BMS limits and protection from the exact datasheet.

Selection matrix

Compare all eight documented GES models.

The model name and published selection values are preserved exactly. Use the interactive cards above for a three-model short list.

GroupModelOutputBatteryPV inputPV Voc maxMPPTChargeParallel
StandardELE GES4862M120-5006.2kW48V9kW500V1 × 27A120ANo
StandardELE GES4880M160-500P8kW48V10kW500V2 × 18A160A1–6
StandardELE GES48100M220-500P10kW48V12kW500V2 × 22A220A1–6
StandardELE GES48120M250-500XP12kW48V24kW500V2 × 32A250A1–6
StandardELE GES48160M300-500XP16kW48V24kW500V2 × 36A300A1–6
PLUSELE GES4880M160-500P-PLUS8kW48V12kW500V2 × 18A160A1–6
PLUSELE GES48120M250-500XP-PLUS12kW48V24kW500V2 × 32A250A1–6
PLUSELE GES48160M300-500XP-PLUS16kW48V24kW500V2 × 36A300A1–6

Source: Household Series Product — Neutral Version — 260721, US quick selection guide page 10. Certification scope, exact interfaces and image-to-model mapping require separate verification.

Suffix discipline

PLUS is a model name—not a blank performance promise.

The selection table shows both standard and PLUS families. At 8kW, the published PV input changes from 10kW to 12kW; the 12kW and 16kW rows show the same headline selection values. Request full datasheets to compare functions not present in the table.

Standard 8kW

ELE GES4880M160-500P

10kW PV input
PLUS 8kW

ELE GES4880M160-500P-PLUS

12kW PV input

Other displayed headline values: 48V battery · 160A charge · 500V PV Voc max · 2 × 18A MPPT · 1–6 parallel.

Split-phase FAQ

Define every conductor and every load.

These answers explain the documented product scope. Exact model data, installation design and local requirements remain controlling.

It is designed for a split-phase AC system with two line conductors and a neutral. In the usual arrangement, line-to-neutral loads use 120Vac and line-to-line loads use 240Vac. Exact wiring and ratings must follow model documentation and local code.

Split-phase inquiry

Send L1, L2 and 240V load data.

Include service voltage, critical circuits by leg, 240V appliances, largest starting load, PV strings, battery model and target backup duration.

Prepare an inquiry

Model comparison

Selected inverter data

Comparison uses quick-selection-guide values. Confirm the complete model datasheet before specification.